FORA: A General-Purpose AI Model for CT Scan Reporting
FORA is a general-purpose AI model designed to interpret CT scans across multiple examination types. Unlike systems built for a narrow set of body regions or abnormalities, it recognizes and spatially...
Key Facts
- Deploy FORA across 12 CT examination types to consolidate interpretation workflows beyond single-region tools.
- Use its 1,028 localized concepts to connect detected findings with scan evidence and draft reports.
- Scale training without manual lesion labeling by learning from routine examinations and radiology reports.
- Validate performance locally: held-out scans achieved a 0.918 macro AUROC for concept recognition.
- Pilot radiologist review workflows to assess report quality, efficiency gains, and clinical fit before adoption.
Summary
Paper: Reliable and grounded reporting of any computed tomography scan with FORA
Authors: Sezgin Er, Utku Turkbey, Alperen Gur, Omer Faruk Durugol, Suprosanna Shit, Murong Xu, Julia Wolleb, Jiayi Wang, Xiaoliang Wang, Hadrien Reynaud, Teodora Spasojevic, Dong Yang, Andriy Myronenko, Pengfei Guo, Yufan He, Can Zhao, Marc Edgar, Andreas Maier, Michael Moor, Mehmet Kemal Ozdemir, Daguang Xu, Bernhard Kainz, Bjoern Menze, Ibrahim Ethem Hamamci
Executive Summary
FORA is a general-purpose AI model designed to interpret CT scans across multiple examination types. Unlike systems built for a narrow set of body regions or abnormalities, it recognizes and spatially localizes 1,028 radiological concepts, then uses those findings to generate reports. The study trained it on 304,962 routine CT examinations and their accompanying reports. Radiologists did not need to mark each lesion by hand: the model learned from the reports.
The system links three tasks: identifying a finding, locating the scan evidence that supports it, and producing a report. The researchers first developed and tested the approach on chest X-rays, then trained a separate model for three-dimensional CT. The reported CT results cover 12 examination types in the final evaluation, while the training cohort included 28 CT protocols.
On 36,619 held-out CT examinations, FORA achieved a macro AUROC of 0.918 for recognizing radiological concepts. AUROC measures how well a model distinguishes cases with a finding from those without it; the macro score averages performance across concepts. FORA’s score was 0.21 higher than that of the strongest of 18 existing CT models in the comparison.
The paper also reports results on three public benchmarks. FORA ranked first on all three and outperformed Merlin on Merlin’s own test set, despite not being trained on data from that institution: AUROC was 0.907 for FORA and 0.826 for Merlin. These are benchmark results, not evidence of improved performance in clinical practice.
The researchers tested localization on separate benchmarks for pulmonary emboli, renal masses and rib fractures. FORA’s strongest spatial evidence fell within annotated lesions at rates up to 348 times greater than chance. This suggests the model can point to relevant areas of a scan, rather than only assign a case-level label. The study also reports more than threefold higher macro-averaged finding recall than the strongest existing report generator. Recall measures how often the system identifies findings that are present; it does not, by itself, establish that every generated report is complete or accurate.
For health systems, the potential value is a single model that could support a broader range of CT interpretation tasks than models tailored to one examination or finding. Learning from routine reports rather than manually labeled lesions may also reduce the need for costly, time-consuming annotation. The results do not establish that FORA is ready for clinical use, reduces radiologists’ workload, or improves patient outcomes. They come from held-out examinations and public or independent benchmarks, not reported real-world deployment.
Academic Abstract
Artificial intelligence systems for computed tomography (CT) remain largely restricted to specific anatomical regions, examination types or predefined abnormalities, limiting their ability to provide comprehensive and spatially grounded interpretations. Here we present FORA, a general-purpose CT model that recognizes and spatially localizes 1,028 hierarchically organized radiological concepts and generates reports across the 28 CT protocols represented in our cohort. Trained on 304,962 routine CT examinations supervised by their accompanying reports, FORA learns to localize abnormalities without manually annotated lesions. Its architecture combines multiple-instance learning with an interpretable concept bottleneck that connects spatial evidence, radiological findings and report generation. We first developed and benchmarked the architecture on chest radiographs, achieving state-of-the-art performance, before training a separate model on three-dimensional CT examinations. On 36,619 held-out CT examinations, FORA achieved a macro area under the receiver operating characteristic curve (AUROC) of 0.918 for radiological concept recognition, exceeding the strongest of 18 existing CT models by 0.21. FORA also ranked first on three public benchmarks, outperforming Merlin on its own test set without training on that institution's data (AUROC 0.907 versus 0.826). On independent localization benchmarks for pulmonary emboli, renal masses and rib fractures, FORA's strongest spatial evidence fell within annotated lesions at rates up to 348 times greater than chance. FORA achieved more than threefold higher macro-averaged finding recall than the strongest existing report generator. These results show that a single model can combine broad abnormality recognition, spatial localization and report generation across 12 CT examination types, using routine reports without lesion-level supervision.
Frequently Asked Questions
What business problem could FORA help address?
FORA is designed to identify radiological concepts in CT scans, localize the supporting scan evidence, and generate reports. It could help address the reporting workload and the need to connect reported findings to evidence, though the summary does not establish specific workflow or productivity gains.
Which industries or organizations may benefit most?
The research directly concerns CT interpretation and reporting, so healthcare organizations that perform CT examinations, such as hospitals or imaging providers, may find it relevant. The summary does not compare benefits across industries or identify particular customers or deployments.
What are the practical implementation considerations?
FORA was trained on routine CT examinations and accompanying reports, and its evaluation covered 12 examination types. Organizations considering implementation may need to assess how well the model fits their own CT protocols and reporting workflows, and how its outputs should be reviewed by clinicians; the summary does not specify deployment requirements.
What resources and expertise might be needed to use FORA?
Applying a system like FORA could require access to CT imaging and reporting workflows, technical expertise to integrate and evaluate the model, and radiology expertise to assess its findings and reports. The summary does not provide details on infrastructure, staffing, or implementation costs.
What competitive advantages could FORA offer?
Its ability to recognize and spatially localize 1,028 radiological concepts across multiple CT examination types could offer broader coverage than systems designed for a narrow set of body regions or abnormalities. Whether that translates into a business advantage would depend on local performance and workflow fit; the summary does not report commercial outcomes.